Basic Info.
Application
Computers, Data Rooms, Communications, Servers
Classification
Lighting/Power
Standby UPS
Sine Wave Output UPS
Product
Three Phase to Three Phase High Frequency UPS 2000
Transport Package
Carton Box or Wooden Pallets
Specification
600*974*1600
Product Description
Three Phase to Three Phase high Frequency UPS 200000va 200kVA/180kw 200000W DC 192V Power Supply CE Certified Long-Acting Machine Pure Sine Wave Online UPS
Product Parameters
MODEL | EX3C3 10K | EX3C3 20K | EX3C3 30K-Q | EX3C3 40K-Q | EX3C3 60K-Q | EX3C3 80K-Q | EX3C3 100K-Q | EX3C3 120K-Q | EX3C3 200K-Q |
CAPACITY | 10KVA/9KW | 20KVA/18KW | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | 80KVA/72KW | 100KVA/90KW | 120KVA/108KW | 200KVA/180KW |
INPUT | |
rated voltage | 3x380VAC/400VAC/415VAC(3-phase +N line) |
Input Voltage Range | 285VAC~475VAC |
|
Frequency Range | 50/60 Hz±10% |
OUTPUT | |
Output Voltage | 3x380VAC/400VAC/415VAC(3-phase +N line) |
Voltage stability | Steady state: ± 1% typical value transient: ± 5% typical value (load change 100-0-100%) |
Frequency Range | 50/60 Hz synchronous ± 1% loss of electricity ± 0.1 Hz |
Frequency tracking rate | ± 1 Hz /s |
Output waveform | Pure Sinewave |
Total Harmonic (THDV) | <2% (linear load) < 5% (nonlinear load) |
Phase unbalance degree | 120 ± 1% (balanced load)120 ± 2% (50% unbalanced load) |
Overload capacity | 110% ~ 150% can run 10MIN ~ 1MIN; 150% ~> 160% CAN RUN 1MIN ~ 200MS; >160% can run 200ms |
Peak factor | 3:01 |
Load power factor range | |
Unbalanced output voltage@100% unbalanced load | <1% |
Protect or restrain | Extremely heavy overload; short circuit; voltage RMS limit; impulse current; peak voltage limit |
Overall efficiency | Online mode | 94% |
Battery mode | 93.50% |
By-pass | |
Types | Static switch |
Voltage | 3x380VAC/400∨AC(3 phase +N line) |
Frequency | 50/60 Hz |
Control Mode | Microprocessor |
Inverter to bypass switching time | Synchronous Mode: Oms asynchronous Mode: 10ms |
Overload capacity | 150%~180%1h~30s;180%∽>200%30s~200ms;200msfor>200% |
Switching to bypass | Overload at 160% : switch now |
Switching back to inverter | Automatic switch after alarm is cleared |
Maintenance bypass | |
Types | Non-stop |
Voltage | 3x400∨(3 phase +N line) |
Frequency | 50/60 Hz |
BATTERY & Charge | |
Number of cells (12V) | 16-20(adjustable) | 32-40(adjustable) |
Charging mode | OPTIONAL: Constant voltage/constant current charging |
Charging current | default 10A, Max = capacity/battery voltage | default 10A, Max 40A |
Battery type | Sealed lead-acid battery |
Structural parameter | |
Dimension,D x W x H (mm) | 592*250*576 | 592*250*576 | 815*300*1000 | 815*300*1000 | 815*300*1000 | 790*360*1010 | 790*360*1010 | 600*974*1600 | 600*974*1600 |
Net Weight (kgs) | 38 | 40 | 64 | 66 | 98 | 113 | 573 | 243 | 340 |
Product Description
Interface Management Function LCD display, real-time recording of UPS working status, parameter information, and so on, to facilitate the user's management of UPS.High Environment Adaptive FunctionCircuit Board placed in a completely closed space, and do "three prevention"coating treatment, more suitable for tunnels, plazas harsh environment.Network Monitoring Function through RS232/RS485 communication interface, SNMP network adaptationPRODUCT FEATURES
Dual transform on-line topology
design with high reliability makes UPS output frequency tracking, phase locking, voltage stabilizing and noise filtering free from grid fluctuation. Pure sine wave power supply, UPS output for the user equipment to provide more comprehensive and perfect protection.
The advanced modular dual CPU control system is reliable and stable to ensure the overall efficiency of UPS operation.
The CPU controls the charging of the current, and the charger charges the current periodically according to the capacity of the battery.
Input Harmonic filters comply with American and European standards, allowing UPS to reduce the pollution of feed-back to the market without affecting other equipment that shares the same market input.
Using advanced PFC Technology, no matter how the load and voltage changes, the input power factor is almost 1.
WIDE AC input voltage range: 380VAC ± 25% , avoid frequent switching to battery supply to adapt to the power environment in poor areas.
The high-frequency filter synchronous circuit is used to quickly track the synchronous frequency and the gradual power, which reduces the requirement of the generator, and the capacity is only 2 times of the input power of UPS.
The input and output are provided with harmonic filters to minimize the harmonic interference of UPS to the Power Grid.
DC start-up function, can be in the state of non-power directly start UPS, to meet the user&#039;s emergency needs.
Perfect protection ability of the whole machine
With output overload protection, output short-circuit protection, inverter over-temperature protection, battery under-voltage Early Warning Protection and battery over-charge protection and other multi-functional protection in one, greatly ensure the stability and reliability of the system operation.
Configuration manual maintenance switch, when the UPS failure, can be uninterrupted to bypass the working state to continue to supply power to the load, so that maintenance easy and convenient.
Optional Intelligent Battery Monitoring Module
Single battery can be tested, with over-voltage, under-voltage and differential pressure alarm function, such as a battery failure on the screen.
Applications
Certifications
Packaging & Shipping
Company Profile
About Berryville
Berryville have been focusing on energy conservation and environmental protection industry, from solar hot water system to solar power generation system, for families, schools, hospitals, factories and others provide all-round energy saving and emission reduction solutions, as well as high-quality and reliable products and optimized system configuration. We offer OEM, ODM and advanced customization services to meet various needs from different clients. Our products have passed UL,CE, IEC, ROHS, SONCAP, SASO,PVOC and other certifications . Berryville has a professional technical team and strictly selected suppliers of high-quality components. They are the valuable wealth of the company and the reliable support of our high-quality system.We hope that our solar energy system can enter all the places that need us in families, farms, factories and so on all over the world. No doubt Berryville is your best are reliable business partner!
FAQ
Q1: Are you a manufacturer or a trading company?
A1: We are a factory more than 20years experience to provide good quality with competitive price.
Q2:How about the delivery time?
A2:Ready sample;7 working days for bulk order after your deposit is confirmed.
Q3:Can you print my logo on the batteries?
A3:Yes, OEM is accepted.
Q4:How many years can be use for battery?
A4:Design life 8-10 years under proper use
Q5:What's the DOD of your battery?
A5:Depend on how deep you use, when power discharge to 20%, 1200 cycle times; when to 50% --800 cycle times; when to 80% ---500 cycle times
Q6:Is it 10HR or 20HR?
A6:4AH to 17AH battery: 20HR, 24AH to 250AH battery: 10HR
Q7: Do you have any certifications for your product?
A7: Yes, CE, UL,RoHS,ISO,MSDS, CNS
Q8: If battery damage,how will you solve the problem?
A8:If there is problem happened , we will gather all the picture and according to your using condition to find out what cause this problem. If it is producing problem, we will replace you the new one in the next shipment.
Q9:What are the price terms can you offer for us?
A9:We accept EXW,FOB,CIF and so on
Address:
Shop No. 1-12, 1st Floor, No. 5 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14001, FSC
Company Introduction:
Berryville group company has more than covers an area of 200000 square meters of production base, the battery and UPS, (inverter) owns two production bases located in Guangdong shaoguan and Guangdong shenzhen. The company has more than 100 professional and technical staff and 500 production staff; Introduced domestic and foreign advanced equipment and instruments, built more than fully automatic production line and the corresponding testing equipment, equipped with automatic plate production line at the same time, realize fully automated health international standards of production, annual output of 275 mkvah (2.75 million kvah), is one of the biggest battery manufacturing centers in China.
Berryville has a back-up, interactive, online high-frequency, power frequency series of household inverter, solar system and other production lines, which is under the IQC, IPQC, QA, QE, 0QC, laboratory, electrical inspection room, finished product inspection room and other eight testing departments, each department is equipped with a variety of precision testing instruments. From raw materials into the warehouse to production assembly out of the warehouse each link to carry out multiple strict control to ensure the flawless quality of products.
Berryville strictly implements the national production safety management system and has the European CE certification, ISO4001, ISO45001, IOS9001 and other certifications. Products sell well in Asia, Africa, Europe, Middle East, America and other more than 100 countries and regions. Warmly welcome people from all walks of life to visit and exchange!